Every gas furnace needs a clear path to get its exhaust outside. In a Southwest Michigan winter, that path gets tested by drifting snow, ice, nests and the slow sag of a pipe that was hung years ago.
Your furnace vent pipe carries combustion gases out of the house. When snow, ice, a nest or a sagging section blocks it, a modern furnace shuts itself off to stay safe. On older furnaces, a blocked or damaged flue can push exhaust, including carbon monoxide, back indoors.
Here is what goes wrong with the furnace vent pipe on both kinds of furnace, what to check after a storm, and when it needs a technician. Most of the checking takes a couple of minutes and a pair of gloves.
High-efficiency furnaces use two white PVC pipes, one bringing in combustion air and one carrying exhaust out. They usually exit through a side wall, sometimes through the roof. The exhaust is too cool and wet for a chimney, so an inducer motor pushes it out, and a pressure switch proves the vent is open before the burners can light.
Older and standard-efficiency furnaces use a metal flue pipe into a masonry chimney or a metal vent through the roof. They rely on hot exhaust rising, and many share that chimney with a gas water heater.
Each type of furnace vent pipe fails in its own way, so the problems below cover both.
Sidewall vents often exit low on the house, not far above the ground. A lake-effect band, a wind-driven drift or snow thrown by a snowblower can bury them overnight. Snow sliding off the roof does the same thing.
When the exhaust or intake is blocked, the pressure switch opens and the furnace stops. The house cools, the thermostat keeps calling, and nothing happens. Of all the reasons a furnace quits after a big storm, a buried furnace vent pipe is one of the easiest to fix yourself.
In deep cold, a high-efficiency furnace puts out a visible white plume. That is water vapor, and it is normal. The problem is where it lands.
On the coldest days, that moisture can freeze on the termination, the siding and the intake pipe beside it, building a little each cycle until the opening narrows. If the plume is regularly drawn back into the intake, the terminations may be too close together or pointed the wrong way. That is an installation issue to correct, not a winter chore.
Birds, wasps and mice all like a small, sheltered pipe. Leaves blow into sidewall terminations in fall, and on older homes, nests and debris fall into chimneys.
Only use a screen or guard the furnace manufacturer approves. The wrong screen can ice over in January and block the furnace vent pipe more completely than a nest would. For chimneys, the CDC warns that debris can block a chimney and cause carbon monoxide to build up inside your home.
Indoors, a PVC exhaust pipe is supposed to slope back toward the furnace so condensate drains into the trap. When a hanger loosens or a section settles, a low spot forms and fills with water.
You may hear gurgling when the furnace runs. The water restricts the exhaust, the pressure switch trips, and the furnace shuts down, often in a stop-and-start pattern that resembles furnace short cycling. A sag can also push water out of a joint, one of the causes in our guide to a furnace leaking water.
The clearances around a vent termination come from the furnace manufacturer’s installation instructions and local code. They keep exhaust away from windows, doors, the gas meter and other air intakes.
A lot can change after the furnace goes in. A new deck, a shrub that filled in, a fence, or the spot where the snow pile always ends up can crowd a termination. Never cover a furnace vent pipe for winter. A cover belongs on the AC condenser, not on a vent.
A metal flue into a masonry chimney depends on an intact liner. Old clay tile liners crack, mortar falls in, and a chimney that is too cold or too large lets exhaust cool, condense and drain back down.
The most overlooked case comes after a furnace upgrade. When a high-efficiency furnace replaces an old one, its venting leaves the chimney, and the gas water heater is left venting alone. That orphaned water heater may not draft well in a chimney sized for two appliances, and it can spill exhaust at its draft hood. It usually needs a properly sized liner.
A venting problem is one of the ways carbon monoxide ends up indoors, which our carbon monoxide and furnace safety guide covers in detail.
Make this part of shoveling the driveway:
A furnace that stopped because of a blocked vent may need its power switched off and on once to restart. If it still will not run, call. If a carbon monoxide alarm sounds, get everyone out and call 911 from outside. Ready.gov recommends working carbon monoxide detectors on every level of your home.
During a fall tune-up, the technician checks the whole vent path: pipe slope and hangers, joints, terminations and their clearances, pressure switch operation, and on natural-draft appliances, draft and spillage at the furnace and water heater. Where drifting snow keeps burying a sidewall vent, the fix may be raising the terminations or rerouting them through the roof.
J&J has kept furnaces venting safely across Hastings, Nashville and the rest of Barry County for over 50 years. Venting corrections are handled as furnace repair, with clear pricing before any work begins. The Comfort Plus Membership includes the fall furnace tune-up at $79 and a reminder postcard.
Yes, on a high-efficiency furnace. The exhaust carries water vapor, and in cold weather it shows up as a white plume and sometimes a few drips. What is not normal is ice building up inside the opening, water pouring from the pipe, or the plume being pulled into the intake.
No. Never cover or wrap a furnace vent pipe or intake, even with something meant to keep snow out. The furnace needs both open every time it runs. If snow keeps burying the terminations, have them raised or rerouted rather than covered.
On a high-efficiency furnace, the pressure switch senses the blockage and stops the burners, so the house cools. Clear the snow by hand, then switch the furnace off and on once. If it does not restart, call for service, since the switch or inducer may need attention.