Ice storms and high winds knock out power across Southwest Michigan every winter. Most of the time, restarting a furnace after power outage repairs takes nothing more than the electricity coming back. Sometimes the lights return and the heat does not.
When a furnace stays off after the power returns, the cause is usually one of four things: the thermostat lost its settings, a breaker or furnace switch tripped, the control board locked out, or a surge damaged a part. You can safely check the first two yourself.
Below is why each one happens, a safe restart sequence, and how to stay warm without creating a carbon monoxide risk while you wait.
A gas furnace depends on electricity as much as on gas. The thermostat signal, inducer motor, ignitor, gas valve, control board and blower all need power, and they have to come back in the right order. A break anywhere in that chain leaves the furnace sitting idle.
Ice storms make it harder. The National Weather Service warns that ice can disrupt power for days while utilities repair extensive damage, and restoration often comes with flickers and short drops before the power holds. Most no-heat calls on a furnace after power outage restoration trace back to one of the four causes below.
Check the thermostat first on any furnace after power outage, because it takes seconds. Many programmable and smart thermostats reboot when power returns. Some go back to factory defaults, lose the schedule or switch the mode to OFF. A smart thermostat may also need to reconnect to Wi-Fi before its app works again.
Confirm the mode is HEAT and the setpoint is a few degrees above room temperature. If the screen is dark, the cause may be dead batteries, a tripped breaker or a blown fuse on the furnace control board. Our guide to a thermostat blank screen walks through each one.
The surge when power returns can trip the furnace breaker. Check the panel for a breaker resting in the middle position, push it fully off, then back on. Reset it once.
Also find the furnace service switch. It looks like a light switch, usually on or near the furnace or at the top of the basement stairs, and it is easy to flip off by mistake when someone is hunting for a flashlight in the dark.
If the breaker trips again, leave it off and call. A breaker that will not hold is protecting you from something, and our article on a furnace tripping the breaker explains the usual culprits.
Every time the power drops in the middle of a start, the furnace loses an ignition attempt. After several failed attempts, many control boards go into lockout and stop trying. That protects the furnace, but it leaves the house cold.
Clearing a lockout on a furnace after power outage is usually simple: turn the furnace switch off, wait a minute, and turn it back on. If it still will not light, look at the status light through the small window in the blower door and compare the blink pattern to the chart on the panel. Our guide to a furnace not turning on explains how to read it.
When power is restored, voltage can spike for an instant. That is hard on the electronics inside a modern furnace: the control board, the transformer that powers the thermostat circuit, and the electronics built into variable-speed blower motors.
Signs of surge damage on a furnace after power outage include no status light at all, a burnt electrical smell at the cabinet, a blown fuse on the control board, or a blower that runs and will not stop. None of those are do-it-yourself repairs. They take a meter and a technician who knows what the readings should be.
Ready.gov recommends disconnecting appliances and electronics during an outage to avoid damage from surges. For a furnace, the simple version is setting the thermostat to OFF until the power has been steady for a few minutes.
Once the power has held steady for a few minutes, work through this in order:
If you smell gas at any point, do not touch switches. Leave the house and call your gas utility from outside.
Heat pump owners have one extra step. After a long outage in very cold weather, some manufacturers recommend leaving the outdoor unit powered but idle for a period so the compressor’s crankcase heater can warm the oil before it runs. Your owner’s manual will say whether yours does.
The most dangerous part of a long winter outage is usually not the cold. It is the improvised heat.
If a carbon monoxide alarm sounds, get everyone outside and call 911. Our carbon monoxide safety guide covers the symptoms and what happens next.
A gas furnace needs only a modest amount of electricity, so many homeowners plan to run it on a generator during the next ice storm. That can work, but the connection matters.
Connecting a generator to a furnace requires a proper transfer switch installed by a licensed electrician. Never power the house by plugging a generator into a wall outlet or dryer receptacle. That can send power back into the utility lines, which endangers line crews and can damage your equipment.
Some control boards and variable-speed blower motors are also sensitive to the power quality from small portable generators. Ask your electrician and the generator manufacturer what your furnace needs before the storm, not during it.
If you have worked through the restart sequence and the furnace after power outage still sits idle, the problem is inside the equipment. J&J has diagnosed no-heat calls across Jackson, Olivet and the rest of our service area for over 50 years. A technician reads the fault codes, tests the board, transformer, fuse and motors, and gives you clear pricing before any furnace repair begins.
Our hours are Monday through Friday, 8:00 a.m. to 5:00 p.m. Calls about a furnace after power outage restoration stack up quickly after a big storm, so you can submit a request through our scheduling page any time and we follow up to confirm the appointment window. Same-day service is sometimes possible, depending on the schedule and technician availability.
Usually not. Most furnaces restart on their own once power returns and the thermostat calls for heat. Resetting a furnace after power outage is only needed when it stays off: check the thermostat, breaker and furnace switch, then turn the switch off for a minute and back on to clear a lockout.
It can. The surge when power is restored can damage a control board, transformer or blower motor electronics, and repeated flickers can push a furnace into lockout. If there is no status light, you smell burning, or the breaker keeps tripping, leave it off and have it tested.
No. Ready.gov advises against using a gas stove or oven to heat your home. Keep generators outdoors and well away from windows and doors, keep carbon monoxide alarms working on every level, and go to a warming location with power if the cold becomes extreme.